Resultados 1 - 20 de 48
Filtrar
1.
Knee ; 28: 383-390, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33408039

RESUMO

BACKGROUND: Cementless fixation is an alternative to cemented unicompartmental knee replacement (UKR). The aim of this study was to determine if cementless UKR fixation is as good as cemented by comparing the five-year migration measured radiostereometric analysis (RSA) in a randomised controlled trial. METHODS: Thirty-nine patients were randomised to receive either a cemented or a cementless Oxford UKR and were studied at intervals up to five years to assess migration with RSA and radiolucencies with radiographs. RESULTS: During the first year there was a small and significant amount of migration, predominantly in an anterior direction, of both the cemented (0.24 mm, SD 0.32, p = 0.01) and cementless (0.26 mm, SD 0.31, p = 0.00) femoral components. Thereafter there was no significant migration in any direction. At no stage was there any significant difference between the migrations of the cemented or cementless femoral components. During the first year, particularly the first three months, the cementless tibial components subsided 0.28 mm (SD 0.19, p = 0.00). This was significantly (p = 0.00) greater than the subsidence of the cemented tibial component (0.09, SD 0.19, p = 0.28). Between the second and fifth years there was no significant migration of either cemented or cementless tibial components. At five years radiolucent lines occurred significantly less with cementless (one partial) compared to cemented (six partial and one complete) tibial components. CONCLUSIONS: As, between two and five years, there was no significant migration of cemented or cementless components, and no significant difference between them, we conclude that cementless fixation is as reliable as cemented. It may be better as there are fewer radiolucent lines.


Assuntos
Artroplastia do Joelho/métodos , Cimentos Ósseos , Prótese do Joelho , Osteoartrite do Joelho/cirurgia , Tíbia/cirurgia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/diagnóstico , Desenho de Prótese , Radiografia , Análise Radioestereométrica , Tíbia/diagnóstico por imagem , Resultado do Tratamento
2.
Bone Joint J ; 99-B(11): 1467-1476, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29092985

RESUMO

AIMS: The optimal method of tibial component fixation remains uncertain in total knee arthroplasty (TKA). Hydroxyapatite coatings have been applied to improve bone ingrowth in uncemented designs, but may only coat the directly accessible surface. As peri-apatite (PA) is solution deposited, this may increase the coverage of the implant surface and thereby fixation. We assessed the tibial component fixation of uncemented PA-coated TKAs versus cemented TKAs. PATIENTS AND METHODS: Patients were randomised to PA-coated or cemented TKAs. In 60 patients (30 in each group), radiostereometric analysis of tibial component migration was evaluated as the primary outcome at baseline, three months post-operatively and at one, two and five years. A linear mixed-effects model was used to analyse the repeated measurements. RESULTS: After five years of follow-up, one (cemented) component was revised due to ligament instability. Overall, uncemented PA-coated tibial components migrated significantly more (p = 0.003), with the mean maximum total point motion (MTPM) at five years being 0.62 mm (95% confidence intervals (CI) 0.49 to 0.76) for cemented tibial components and 0.97 mm (95% CI 0.81 to 1.15) for PA-coated tibial components in TKA. However, between three months and five years the cemented TKAs migrated significantly more (p = 0.02), displaying a MTPM of 0.27 mm (95% CI, 0.19 to 0.36) versus 0.13 mm (95% CI, 0.01 to 0.25) for PA-coated tibial components. One implant in each group was considered at risk for aseptic loosening due to continuous migration after five years of follow-up, albeit with different migration patterns for each group (i.e. higher initial migration but diminishing over time for the PA-coated component versus gradually increasing migration for the cemented component). CONCLUSION: The tibial components of PA-coated TKAs showed more overall migration compared with the tibial components of cemented TKAs. However, post hoc analysis showed that this difference was caused by higher migration of PA-coated components in the first three months, after which a stable migration pattern was observed. Clinically, there was no significant difference in outcome between the groups. Cite this article: Bone Joint J 2017;99-B:1467-76.


Assuntos
Apatitas , Artroplastia do Joelho/instrumentação , Cimentos Ósseos , Materiais Revestidos Biocompatíveis , Prótese do Joelho , Osteoartrite do Joelho/cirurgia , Falha de Prótese , Adulto , Idoso , Feminino , Seguimentos , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/diagnóstico por imagem , Análise Radioestereométrica , Resultado do Tratamento
3.
Bone Joint J ; 98-B(10): 1333-1341, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27694586

RESUMO

AIMS: The widely used and well-proven Palacos R (a.k.a. Refobacin Palacos R) bone cement is no longer commercially available and was superseded by Refobacin bone cement R and Palacos R + G in 2005. However, the performance of these newly introduced bone cements have not been tested in a phased evidence-based manner, including roentgen stereophotogrammetric analysis (RSA). PATIENTS AND METHODS: In this blinded, randomised, clinical RSA study, the migration of the Stanmore femoral component was compared between Refobacin bone cement R and Palacos R + G in 62 consecutive total hip arthroplasties. The primary outcome measure was femoral component migration measured using RSA and secondary outcomes were Harris hip score (HHS), Hip disability and Osteoarthritis Outcome Score (HOOS), EuroQol 5D (EQ-5D) and Short Form 36 (SF-36). RESULTS: Femoral component migration was comparable between Refobacin bone cement R and Palacos R + G during the two-year follow-up period with an estimated mean difference of 0.06 mm of subsidence (p = 0.56) and 0.08° of retroversion (p = 0.82). Five hips (three Refobacin bone cement R and two Palacos R + G) showed non-stabilising, continuous migration; the femoral cement mantle in these hips, was mean 0.7 mm thicker (p = 0.02) and there were more radiolucencies at the bone-cement interface (p = 0.004) in comparison to hips showing stabilising migration. Post-operative HHS was comparable throughout the follow-up period (p = 0.62). HOOS, EQ5D, and SF-36 scores were also comparable (p-values > 0.05) at the two-year follow-up point. CONCLUSION: Refobacin bone cement R and Palacos R + G show comparable component migration and clinical outcome during the first two post-operative years. Hips showing continuous migration are at risk for early failure. However, this seems to be unrelated to cement type, but rather to cementing technique. Cite this article: Bone Joint J 2016;98-B:1333-41.


Assuntos
Artroplastia de Quadril/métodos , Gentamicinas/farmacologia , Articulação do Quadril/cirurgia , Prótese de Quadril , Metilmetacrilatos/farmacologia , Osteoartrite do Quadril/cirurgia , Polimetil Metacrilato/farmacologia , Análise Radioestereométrica/métodos , Adulto , Idoso , Cimentos Ósseos , Feminino , Seguimentos , Articulação do Quadril/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/diagnóstico , Desenho de Prótese , Estudos Retrospectivos , Método Simples-Cego
4.
Bone Joint Res ; 5(8): 320-7, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27491660

RESUMO

OBJECTIVES: An important measure for the diagnosis and monitoring of knee osteoarthritis is the minimum joint space width (mJSW). This requires accurate alignment of the x-ray beam with the tibial plateau, which may not be accomplished in practice. We investigate the feasibility of a new mJSW measurement method from stereo radiographs using 3D statistical shape models (SSM) and evaluate its sensitivity to changes in the mJSW and its robustness to variations in patient positioning and bone geometry. MATERIALS AND METHODS: A validation study was performed using five cadaver specimens. The actual mJSW was varied and images were acquired with variation in the cadaver positioning. For comparison purposes, the mJSW was also assessed from plain radiographs. To study the influence of SSM model accuracy, the 3D mJSW measurement was repeated with models from the actual bones, obtained from CT scans. RESULTS: The SSM-based measurement method was more robust (consistent output for a wide range of input data/consistent output under varying measurement circumstances) than the conventional 2D method, showing that the 3D reconstruction indeed reduces the influence of patient positioning. However, the SSM-based method showed comparable sensitivity to changes in the mJSW with respect to the conventional method. The CT-based measurement was more accurate than the SSM-based measurement (smallest detectable differences 0.55 mm versus 0. 82 mm, respectively). CONCLUSION: The proposed measurement method is not a substitute for the conventional 2D measurement due to limitations in the SSM model accuracy. However, further improvement of the model accuracy and optimisation technique can be obtained. Combined with the promising options for applications using quantitative information on bone morphology, SSM based 3D reconstructions of natural knees are attractive for further development.Cite this article: E. A. van IJsseldijk, E. R. Valstar, B. C. Stoel, R. G. H. H. Nelissen, N. Baka, R. van't Klooster, B. L. Kaptein. Three dimensional measurement of minimum joint space width in the knee from stereo radiographs using statistical shape models. Bone Joint Res 2016;320-327. DOI: 10.1302/2046-3758.58.2000626.

5.
J Biomech ; 48(14): 3837-45, 2015 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-26435183

RESUMO

Fluoroscopy-derived joint kinematics plays an important role in the evaluation of knee prostheses. Fluoroscopic analysis requires estimation of the 3D prosthesis pose from its 2D silhouette in the fluoroscopic image, by optimizing a dissimilarity measure. Currently, extensive user-interaction is needed, which makes analysis labor-intensive and operator-dependent. The aim of this study was to review five optimization methods for 3D pose estimation and to assess their performance in finding the correct solution. Two derivative-free optimizers (DHSAnn and IIPM) and three gradient-based optimizers (LevMar, DoNLP2 and IpOpt) were evaluated. For the latter three optimizers two different implementations were evaluated: one with a numerically approximated gradient and one with an analytically derived gradient for computational efficiency. On phantom data, all methods were able to find the 3D pose within 1mm and 1° in more than 85% of cases. IpOpt had the highest success-rate: 97%. On clinical data, the success rates were higher than 85% for the in-plane positions, but not for the rotations. IpOpt was the most expensive method and the application of an analytically derived gradients accelerated the gradient-based methods by a factor 3-4 without any differences in success rate. In conclusion, 85% of the frames can be analyzed automatically in clinical data and only 15% of the frames require manual supervision. The optimal success-rate on phantom data (97% with IpOpt) on phantom data indicates that even less supervision may become feasible.


Assuntos
Artroplastia do Joelho , Fluoroscopia/métodos , Imageamento Tridimensional/métodos , Prótese do Joelho , Fenômenos Biomecânicos , Simulação por Computador , Humanos , Imagens de Fantasmas
6.
Bone Joint J ; 97-B(2): 185-91, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25628280

RESUMO

The most common reasons for revision of unicompartmental knee arthroplasty (UKA) are loosening and pain. Cementless components may reduce the revision rate. The aim of this study was to compare the fixation and clinical outcome of cementless and cemented Oxford UKAs. A total of 43 patients were randomised to receive either a cemented or a cementless Oxford UKA and were followed for two years with radiostereometric analysis (RSA), radiographs aligned with the bone-implant interfaces and clinical scores. The femoral components migrated significantly during the first year (mean 0.2 mm) but not during the second. There was no significant difference in the extent of migration between cemented and cementless femoral components in either the first or the second year. In the first year the cementless tibial components subsided significantly more than the cemented components (mean 0.28 mm (sd 0.17) vs. 0.09 mm (sd 0.19 mm)). In the second year, although there was a small amount of subsidence (mean 0.05 mm) there was no significant difference (p = 0.92) between cemented and cementless tibial components. There were no femoral radiolucencies. Tibial radiolucencies were narrow (< 1 mm) and were significantly (p = 0.02) less common with cementless (6 of 21) than cemented (13 of 21) components at two years. There were no complete radiolucencies with cementless components, whereas five of 21 (24%) cemented components had complete radiolucencies. The clinical scores at two years were not significantly different (p = 0.20). As second-year migration is predictive of subsequent loosening, and as radiolucency is suggestive of reduced implant-bone contact, these data suggest that fixation of the cementless components is at least as good as, if not better than, that of cemented devices.


Assuntos
Artroplastia do Joelho/métodos , Idoso , Cimentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/cirurgia , Falha de Prótese , Análise Radioestereométrica , Dosagem Radioterapêutica , Estudos Retrospectivos , Resultado do Tratamento
7.
Bone Joint Res ; 3(10): 289-96, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25278502

RESUMO

INTRODUCTION: Wear of polyethylene inserts plays an important role in failure of total knee replacement and can be monitored in vivo by measuring the minimum joint space width in anteroposterior radiographs. The objective of this retrospective cross-sectional study was to compare the accuracy and precision of a new model-based method with the conventional method by analysing the difference between the minimum joint space width measurements and the actual thickness of retrieved polyethylene tibial inserts. METHOD: Before revision, the minimum joint space width values and their locations on the insert were measured in 15 fully weight-bearing radiographs. These measurements were compared with the actual minimum thickness values and locations of the retrieved tibial inserts after revision. RESULTS: The mean error in the model-based minimum joint space width measurement was significantly smaller than the conventional method for medial condyles (0.50 vs 0.94 mm, p < 0.01) and for lateral condyles (0.06 vs 0.34 mm, p = 0.02). The precision (standard deviation of the error) of the methods was similar (0.84 vs 0.79 mm medially and both 0.46 mm laterally). The distance between the true minimum joint space width locations and the locations from the model-based measurements was less than 10 mm in the medial direction in 12 cases and less in the lateral direction in 13 cases. CONCLUSION: The model-based minimum joint space width measurement method is more accurate than the conventional measurement with the same precision. Cite this article: Bone Joint Res 2014;3:289-96.

8.
J Biomech ; 47(13): 3334-43, 2014 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-25171786

RESUMO

It has been recently suggested that mechanical loads applied at frequencies close to the natural frequencies of bone could enhance bone apposition due to the resonance phenomenon. Other applications of bone modal analysis are also suggested. For the above-mentioned applications, it is important to understand how patient-specific bone shape and density distribution influence the natural frequencies of bones. We used finite element models to study the effects of bone shape and density distribution on the natural frequencies of the femur in free boundary conditions. A statistical shape and appearance model that describes shape and density distribution independently was created, based on a training set of 27 femora. The natural frequencies were then calculated for different shape modes varied around the mean shape while keeping the mean density distribution, for different appearance modes around the mean density distribution while keeping the mean bone shape, and for the 27 training femora. Single shape or appearance modes could cause up to 15% variations in the natural frequencies with certain modes having the greatest impact. For the actual femora, shape and density distribution changed the natural frequencies by up to 38%. First appearance mode that describes the general cortical bone thickness and trabecular bone density had one of the strongest impacts. The first appearance mode could therefore provide a sensitive measure of general bone health and disease progression. Since shape and density could cause large variations in the calculated natural frequencies, patient-specific FE models are needed for accurate estimation of bone natural frequencies.


Assuntos
Densidade Óssea , Fêmur/anatomia & histologia , Fêmur/fisiologia , Análise de Elementos Finitos , Vibração , Feminino , Fêmur/diagnóstico por imagem , Humanos , Masculino , Modelagem Computacional Específica para o Paciente , Tomografia Computadorizada por Raios X
9.
Clin Biomech (Bristol, Avon) ; 29(7): 742-6, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25001328

RESUMO

BACKGROUND: In vitro cadaveric studies showed that elastomer femoroplasty prevents displacement of fracture parts after proximal hip fracture allowing for conservative treatment. In the event that secondary displacement does occur, the purpose of this present study was to determine the feasibility of performing osteosynthesis of a fractured hip after preventive treatment with elastomer femoroplasty. METHODS: Ten pairs of human cadaveric femurs were fractured in a simulated fall configuration. From each pair, one femur was randomly selected for elastomer femoroplasty prior to fracture generation and the contralateral femur was used as control. Following hip fracture generation, osteosynthesis was performed in all femurs. The operative time per case, technical difficulties during the procedure, and postoperative energy-to-failure load were recorded. RESULTS: The mean (SD) time to perform osteosynthesis was 20 (6) minutes in the control-group and 19 (5) minutes in the elastomer femoroplasty-group (P=0.69). During osteosynthesis of the fractured hip in the elastomer femoroplasty-group, no difficulties including the need for additional instruments to remove elastomer from the proximal femur were recorded. Postoperative energy-to-failure load was similar in the control-group and the elastomer femoroplasty-group. CONCLUSION: Fixation with routine osteosynthesis of displaced cadaveric hip fractures is not hindered by the presence of previously injected elastomer.


Assuntos
Fixação Interna de Fraturas/métodos , Fraturas do Quadril/cirurgia , Quadril/cirurgia , Idoso , Idoso de 80 Anos ou mais , Cadáver , Elastômeros , Estudos de Viabilidade , Feminino , Fêmur/cirurgia , Humanos , Masculino , Reprodutibilidade dos Testes , Estresse Mecânico , Resultado do Tratamento
10.
J Biomech ; 47(7): 1682-8, 2014 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-24636719

RESUMO

Knee contact mechanics play an important role in knee implant failure and wear mechanics. Femoral condylar contact loss in total knee arthroplasty has been reported in some studies and it is considered to potentially induce excessive wear of the polyethylene insert.Measuring in vivo forces applied to the tibial plateau with an instrumented prosthesis is a possible approach to assess contact loss in vivo, but this approach is not very practical. Alternatively, single-plane fluoroscopy and pose estimation can be used to derive the relative pose of the femoral component with respect to the tibial plateau and estimate the distance from the medial and lateral parts of the femoral component towards the insert. Two measures are reported in the literature: lift-off is commonly defined as the difference in distance between the medial and lateral condyles of the femoral component with respect to the tibial plateau; separation is determined by the closest distance of each condyle towards the polyethylene insert instead of the tibia plateau.In this validation study, lift-off and separation as measured with single-plane fluoroscopy are compared to in vivo contact forces measured with an instrumented knee implant. In a phantom study, lift-off and separation were compared to measurements with a high quality bi-plane measurement.The results of the in vivo contact-force experiment demonstrate a large discrepancy between single-plane fluoroscopy and the in vivo force data: single-plane fluoroscopy measured up to 5.1mm of lift-off or separation, whereas the force data never showed actual loss of contact. The phantom study demonstrated that the single-plane setup could introduce an overestimation of 0.22mm±±0.36mm. Correcting the out-of-plane position resulted in an underestimation of medial separation by -0.20mm±±0.29mm.In conclusion, there is a discrepancy between the in vivo force data and single-plane fluoroscopic measurements. Therefore contact loss may not always be determined reliably by single plane fluoroscopy analysis.


Assuntos
Fêmur/fisiologia , Prótese do Joelho , Tíbia/fisiologia , Artroplastia do Joelho/métodos , Fenômenos Biomecânicos , Fêmur/diagnóstico por imagem , Fluoroscopia , Humanos , Polietileno , Tíbia/diagnóstico por imagem
11.
Bone Joint J ; 95-B(9): 1209-16, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23997134

RESUMO

Mobile-bearing (MB) total knee replacement (TKR) was introduced to reduce the risk of aseptic loosening and wear of polyethylene inserts. However, no consistent clinical advantages of mobile- over fixed-bearing (FB) TKR have been found. In this study we evaluated whether mobile bearings have an advantage over fixed bearings with regard to revision rates and clinical outcome scores. Furthermore, we determined which modifying variables affected the outcome. A systematic search of the literature was conducted to collect clinical trials comparing MB and FB in primary TKR. The primary outcomes were revision rates for any reason, aseptic loosening and wear. Secondary outcomes included range of movement, Knee Society score (KSS), Oxford knee score (OKS), Short-Form 12 (SF-12) score and radiological parameters. Meta-regression techniques were used to explore factors modifying the observed effect. Our search yielded 1827 publications, of which 41 studies met our inclusion criteria, comprising over 6000 TKRs. Meta-analyses showed no clinically relevant differences in terms of revision rates, clinical outcome scores or patient-reported outcome measures between MB and FB TKRs. It appears that theoretical assumptions of superiority of MB over FB TKR are not borne out in clinical practice.


Assuntos
Artroplastia do Joelho/métodos , Prótese do Joelho , Osteoartrite do Joelho/cirurgia , Falha de Prótese , Humanos , Osteoartrite do Joelho/fisiopatologia , Satisfação do Paciente , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Reoperação/estatística & dados numéricos , Resultado do Tratamento
12.
J Biomech ; 46(7): 1387-91, 2013 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-23540721

RESUMO

Implant failure related to polyethylene wear remains an important issue in total knee arthroplasty. Polyethylene wear is usually assessed in vivo by measuring the remaining insert thickness on X-ray images of the knee. To reflect the amount of wear debris more accurately, a 3-dimensional overlap measurement has been suggested, which is based on implant component models which are matched on calibrated stereo X-ray images using model-based roentgen stereophotogrammatic analysis. The goal of this study was to determine the influence of pose estimation, insert thickness deviation and variation in the femoral-tibial contact location on the accuracy and precision of the measurement using simulations and a phantom experiment. We found that the pose estimation was the largest source of variation. The 95% prediction interval varied between 111 and 283 mm(3), which is approximately 100-200% of the detected volumetric wear. Insert thickness variation resulted in prediction intervals of 74-174 mm(3). Variation of the femoral-tibial contact location in the phantom experiment gave a prediction interval of 40 mm(3). Large differences in the detected wear volume were found for different flexion angles. At most 56% of the true wear volume was detected (129 of 230 mm(3), 30° of flexion). In summary, both the accuracy and precision of the volumetric wear measurement were low. The prediction interval of the volumetric wear measurement is at least as large as the measurement outcome itself. This is an important limitation to the applicability of the volumetric wear measurement in clinical practice and further clinical validation is required.


Assuntos
Artroplastia do Joelho , Fêmur , Prótese do Joelho , Modelos Biológicos , Tíbia , Humanos
13.
J Bone Joint Surg Br ; 94(10): 1366-71, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23015562

RESUMO

This single-blinded randomised controlled trial investigated whether one design of mobile-bearing (MB) total knee replacement (TKR) has any advantage over a fixed-bearing (FB) design on long-term fixation as measured by radiostereometry. The amount of wear underneath the mobile bearing was also evaluated. A series of 42 knees was randomised to MB or FB tibial components with appropriate polyethylene inserts and followed for between ten and 12 years, or until the death of the patient. The polyethylene in the MB group was superior in that it was gamma-irradiated in inert gas and was calcium-stearate free; the polyethylene in the FB group was gamma-irradiated in air and contained calcium stearate. In theory this should be advantageous to the wear rate of the MB group. At final follow-up the overall mean migration was 0.75 mm (SD 0.76) in the MB group and 0.66 mm (SD 0.4) in the FB group, with the FB group demonstrating more posterior tilt and the MB group more internal rotation. In the FB group there was one revision for aseptic loosening, but none in the MB group. There were no significant differences in clinical or radiological scores. For the MB group, the mean linear wear rate on the under-surface was 0.026 mm/year (SD 0.014). This was significantly smaller than the wear rate of 0.11 mm/year (SD 0.06) in the MB between femur and polyethylene (p < 0.001). Nevertheless, even in a best-case setting the mobile bearings of this TKR design had no apparent advantage in terms of fixation over the FB knee prosthesis at ten to 12 years. The wear underneath the mobile bearing was small and is unlikely to be clinically relevant.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Análise Radioestereométrica , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Método Simples-Cego , Fatores de Tempo
14.
J Biomech ; 45(12): 2171-5, 2012 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-22748324

RESUMO

Excessive wear in total knee arthroplasty is detected by measuring the minimum joint space width (mJSW) in anterioposterior radiographs. The accuracy of conventional measurement methods is limited and can be improved using model-based techniques. In this study, the model-based wear measurement (MBWM) is introduced. Its accuracy and reproducibility are assessed and compared to the conventional measurement. Forty anterioposterior radiographs were obtained of a knee prosthesis using a phantom setup. Both measurement methods were applied and the accuracy and precision were compared. The reproducibility was calculated with inter- and intra-observer experiments. Three observers measured the mJSW in 30 clinical radiographs with both the conventional measurement and the MBWM and repeated this after 6 weeks. The experiments were conducted with a NexGen mobile bearing and fixed bearing prostheses. In the phantom experiment, the accuracy (mean of the absolute error) was significantly higher (t-test, p<0.01) for the MBWM as for the conventional measurement (0.15 mm versus 0.43 mm, 0.14 mm versus 0.35 mm for the mobile and fixed bearing, respectively). The standard deviation of the measurements is the smallest for the MBWM measurement for both prosthesis types (0.16 mm versus 0.47 mm, Levene's test, p<0.01). In the reproducibility experiment, both the intra- and inter-observer agreements were higher for the MBWM than for the conventional method. The results show that the MBWM is superior to the conventional measurement in both accuracy and reproducibility. Although the use of a phantom experiment poses some limitations in conveying the findings to clinical practice, this improved mJSW measurement can lead to better wear detection for surgery decisions and research purposes.


Assuntos
Artroplastia do Joelho/métodos , Análise de Falha de Equipamento/métodos , Articulação do Joelho/diagnóstico por imagem , Prótese do Joelho , Modelos Biológicos , Desenho de Prótese , Humanos , Masculino , Variações Dependentes do Observador , Imagens de Fantasmas , Radiografia
15.
Clin Biomech (Bristol, Avon) ; 27(8): 819-23, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22682558

RESUMO

BACKGROUND: Elastomer femoroplasty is a novel and experimental approach in the prevention of hip fracture surgery. Previously, we published the results of an in vitro cadaveric experiment in which we showed a significant reduction of fracture displacement in treated femurs. The aim of the present study was to establish the failure loads and inter-fragmentary movement of fractured, elastomer femoroplasty treated femurs during cyclic loading. METHODS: 16 cadaveric femurs were treated with elastomer femoroplasty and fractured in a simulated fall configuration. Each specimen underwent 10 cycles with a preload of 50 N, starting with a peak load of 250 N followed by 10 cycles of 500 N and continued with 500 N increments. The crosshead speed was 2 mm/s. The failure load, the number of completed cycles, and crosshead extensions were recorded. FINDINGS: The mean failure load was 2709 N (SD 1094). The number of completed cycles until failure was 60 (SD 22). The mean translation during maximum loading was 5.25 mm (SD 0.9). At 1500 N (two times the bodyweight of a 75 kg individual) the extension was 3.16 mm. INTERPRETATION: Preventive elastomer femoroplasty leads to the stabilization of the proximal femur after fracture. In a single leg stance configuration, cyclic loading with mean failure loads that well exceed the peak loads during normal gait is feasible.


Assuntos
Fraturas do Fêmur/fisiopatologia , Fraturas do Quadril/fisiopatologia , Idoso , Fenômenos Biomecânicos , Densidade Óssea , Parafusos Ósseos , Cadáver , Força Compressiva , Dimetilpolisiloxanos/química , Elastômeros , Feminino , Fraturas do Fêmur/cirurgia , Fêmur/cirurgia , Marcha , Fraturas do Quadril/cirurgia , Humanos , Técnicas In Vitro , Masculino , Teste de Materiais , Estresse Mecânico , Resistência à Tração
16.
Clin Biomech (Bristol, Avon) ; 27(8): 807-12, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22583907

RESUMO

BACKGROUND: Cement injection into osteolytic areas around the cement mantle is a technique for refixation of loose hip implants for patients who cannot undergo standard revision surgery. Preliminary clinical results show the improvement in walking distance, patients' independence and pain relief. METHODS: In this study, we use a detailed finite element model to analyze whether cement injection into osteolytic areas contributes to the overall implant stability. We study the effect of various factors, like location and size of osteolytic areas, interface conditions and bone stiffness on bone-cement relative motion. FINDINGS: Presented results demonstrate that the procedure is most effective for the osteolytic areas located in the proximal region of the femur, while factors like a thin layer of residual fibrous tissue around the injected cement, that was not removed during the surgery, combined with reduced bone stiffness reduce the efficiency of the procedure. INTERPRETATION: Cement injection is able to stabilize loosened hip prostheses. However, it is important to remove the fibrous tissue layer completely, as even a thin layer will negatively influence stabilization. We will focus our research efforts on developing fibrous tissue removal techniques in order to optimize this minimally invasive treatment.


Assuntos
Cimentos Ósseos/química , Prótese de Quadril , Quadril/cirurgia , Idoso , Artroplastia de Quadril/métodos , Osso e Ossos/patologia , Cimentação/métodos , Módulo de Elasticidade , Análise de Elementos Finitos , Quadril/fisiopatologia , Humanos , Masculino , Modelos Anatômicos , Osteólise , Reoperação , Tomografia Computadorizada por Raios X/métodos
17.
Knee Surg Sports Traumatol Arthrosc ; 20(12): 2487-93, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22426852

RESUMO

PURPOSE: Limited or absent axial rotation of the mobile insert of total knee prostheses could lead to high contact stresses and stresses at the bone-implant interface, which in turn might lead to implant loosening. The aim of this study was to assess knee kinematics and muscle activation and their possible change over time in patients with a highly congruent, mobile-bearing total knee prosthesis. METHODS: A prospective series of 11 rheumatoid arthritis patients was included to participate in this fluoroscopic and EMG study; only 7 patients completed the study. Kinematic evaluations took place 7 months, 1 and 2 years post-operatively. Repeated measurements ANOVA and linear mixed-effects model for longitudinal data were used to compare the differences between the follow-ups. RESULTS: There are no significant changes in axial rotations between follow-up moments for the femoral component as well as the mobile insert. The insert remained mobile and followed the femoral component from 0° until approximately 60° of knee flexion. Diverging and reversed axial rotations and translations were seen during the dynamic motions. CONCLUSIONS: Knee kinematics and muscle activation do not appear to change in the first 2 post-operative years. Reversed and divergent axial rotations with increasing knee flexion indicate that as soon as the congruency decreases, the femoral component is no longer forced in a certain position by the insert and moves to a self-imposed position. At lower knee flexion angles, the femoral component might be obstructed by the highly congruent insert and therefore might not be able to move freely. LEVEL OF EVIDENCE: Therapeutic study, Level IV.


Assuntos
Artrite Reumatoide/cirurgia , Artroplastia do Joelho/instrumentação , Articulação do Joelho/cirurgia , Prótese do Joelho , Desenho de Prótese , Idoso , Fenômenos Biomecânicos , Eletromiografia , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Amplitude de Movimento Articular
18.
Clin Biomech (Bristol, Avon) ; 27(4): 398-402, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22055272

RESUMO

BACKGROUND: The mobile-bearing variant of a single-radius design is assumed to provide more freedom of motion compared to the fixed-bearing variant because the insert does not restrict the natural movements of the femoral component. This would reduce the contact stresses and wear which in turn may have a positive effect on the fixation of the prosthesis to the bone and thereby decreases the risk for loosening. The aim of this study was to evaluate early migration of the tibial component and kinematics of a mobile-bearing and fixed-bearing total knee prosthesis of the same single-radius design. METHODS: Twenty Triathlon single-radius posterior-stabilized knee prostheses were implanted (9 mobile-bearing and 11 fixed-bearing). Fluoroscopy and roentgen stereophotogrammetric analysis (RSA) were performed 6 and 12 months post-operatively. FINDINGS: The 1 year post-operative RSA results showed considerable early migrations in 3 out of 9 mobile-bearing patients and 1 out of 11 fixed-bearing patients. The range of knee flexion was the same for the mobile-bearing and fixed-bearing group. The mobile insert was following the femoral component during motion. INTERPRETATION: Despite the mobile insert following the femoral component during motion, and therefore performing as intended, no kinematic advantages of the mobile-bearing total knee prosthesis were seen. The fixed-bearing knee performed as good as the mobile-bearing knee and maybe even slightly better based on less irregular kinematics and less early migrations.


Assuntos
Artroplastia do Joelho/instrumentação , Instabilidade Articular/fisiopatologia , Instabilidade Articular/cirurgia , Articulação do Joelho/fisiopatologia , Articulação do Joelho/cirurgia , Prótese do Joelho , Amplitude de Movimento Articular , Idoso , Artroplastia do Joelho/métodos , Análise de Falha de Equipamento , Feminino , Humanos , Instabilidade Articular/etiologia , Pessoa de Meia-Idade , Desenho de Prótese , Resultado do Tratamento
19.
Knee Surg Sports Traumatol Arthrosc ; 20(3): 559-64, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21761233

RESUMO

PURPOSE: The aim of this study was to compare a broad range of total knee prostheses with different design parameters to determine whether in vivo kinematics was consistently related to design. The hypothesis was that there are no clear recognizable differences in in vivo kinematics between different design parameters or prostheses. METHODS: At two sites, data were collected by a single observer on 52 knees (49 subjects with rheumatoid arthritis or osteoarthritis). Six different total knee prostheses were used: multi-radius, single-radius, fixed-bearing, mobile-bearing, posterior-stabilized, cruciate retaining and cruciate sacrificing. Knee kinematics was recorded using fluoroscopy as the patients performed a step-up motion. RESULTS: There was a significant effect of prosthetic design on all outcome parameters; however, post hoc tests showed that the NexGen group was responsible for 80% of the significant values. The range of knee flexion was much smaller in this group, resulting in smaller anterior-posterior translations and rotations. CONCLUSION: Despite kinematics being generally consistent with the kinematics intended by their design, there were no clear recognizable differences in in vivo kinematics between different design parameters or prostheses. Hence, the differences in design parameters or prostheses are not distinct enough to have an effect on clinical outcome of patients. LEVEL OF EVIDENCE: Therapeutic study, Level III.


Assuntos
Prótese do Joelho , Desenho de Prótese , Idoso , Artrite Reumatoide/cirurgia , Fenômenos Biomecânicos , Feminino , Fluoroscopia , Humanos , Articulação do Joelho/fisiologia , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/cirurgia , Amplitude de Movimento Articular
20.
Proc Inst Mech Eng H ; 225(8): 753-61, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21922952

RESUMO

With fluoroscopic analysis of knee implant kinematics the implant contour must be detected in each image frame, followed by estimation of the implant pose. With a large number of possibly low-quality images, the contour detection is a time-consuming bottleneck. The present paper proposes an automated contour detection method, which is integrated in the pose estimation. In a phantom experiment the automated method was compared with a standard method, which uses manual selection of correct contour parts. Both methods demonstrated comparable precision, with a minor difference in the Y-position (0.08 mm versus 0.06 mm). The precision of each method was so small (below 0.2 mm and 0.3 degrees) that both are sufficiently accurate for clinical research purposes. The efficiency of both methods was assessed on six clinical datasets. With the automated method the observer spent 1.5 min per image, significantly less than 3.9 min with the standard method. A Bland-Altman analysis between the methods demonstrated no discernible trends in the relative femoral poses. The threefold increase in efficiency demonstrates that a pose estimation approach with integrated contour detection is more intuitive than a standard method. It eliminates most of the manual work in fluoroscopic analysis, with sufficient precision for clinical research purposes.


Assuntos
Fluoroscopia/métodos , Prótese do Joelho , Imagens de Fantasmas , Fenômenos Biomecânicos , Bioestatística/métodos , Simulação por Computador , Humanos , Imageamento Tridimensional/instrumentação